Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No: SPST300VAC12000W-4-17
Merek: APM
Tempat Asal: Cina
Input Voltage: 190~265v
Input Frequency: 47~63hz
Power Factor: ≥0.99
Max.Current: 75a
Height: 17u
Warranty: 2 Years
Interface: Rs232/Rs485/Usb(Standard)
AC Power(Total): 12000va
AC Power(Per Phase): 4000va
Kemasan: Kotak kayu
Produktivitas: OTHER
Transportasi: Air
Tempat asal: CINA
Dukungan tentang: OTHER
Sertifikat: ISO9001
Kode HS: 8504401500
Pelabuhan: DHL
Jenis pembayaran: T/T
Inkoterm: EXW
APM AC Power Supply tersedia dengan 10.8KVA. Berbagai macam pengujian peralatan tipe komersial, militer, industri dan penerbangan dicakup oleh model ini. Sumber daya lab ini menawarkan solusi sempurna untuk memenuhi persyaratan pasar dengan memberikan kemampuan untuk mensimulasikan berbagai Kondisi input garis AC dan pengukuran fitur penting untuk produk yang diuji. Sumber daya output DC dan AC ini, unit catu daya laboratorium mencakup kisaran tegangan hingga 300VAC dan arus hingga 32A . Ada lebih banyak model, sumber AC Fase 300W 3 fase 3000W 3 fase 3000W, sumber AC 3500W 3 fase, 6000W 3 fase 3 fase 3000W Sumber AC, Sumber AC 9000W 3 Fase, 15000W 3 Fase AC Sumber untuk referensi Anda.
Area aplikasi :
Seri ini berlaku untuk beberapa sektor seperti sektor listrik, pencahayaan dan penerbangan dan dapat diterapkan pada tes produksi Enterprise juga.
Fitur Produk:
● Layar warna sentuh besar 5.6``, memiliki fungsi lengkap dan mudah dioperasikan.
● Dukungan untuk Impor/Ekspor Data USB dan snap layar dari panel depan.
● Mode output campuran atau independen AC+DC untuk simulasi offset DC tegangan.
● Mampu mengatur tegangan dan pembatasan output arus, dukungan untuk mode output arus konstan.
● Mampu mengatur kemiringan output tegangan dan frekuensi.
● Mampu mengatur/mematikan sudut fase.
● Dengan perlindungan arus terbalik untuk menghindari arus yang mengalir ke belakang.
● Meter daya bawaan, yang mampu mengukur 5 parameter listrik per fase, termasuk tegangan, arus, daya, dll.
● Mendukung fungsi pengukuran arus MA.
Fungsi dasar:
1. Sudut/kemiringan fase yang dapat disesuaikan
Sudut/kemiringan fase yang dapat disesuaikan berlaku untuk uji verifikasi pengujian arus inrush on/off. Fungsi ini berlaku untuk memulai beban induktif atau kapasitif dengan kapasitas besar untuk menghindari arus tinggi ketika secara instan memulai perangkat.
2. Faktor puncak output tinggi saat ini
Arus lonjakan dapat mencapai 5-6 kali arus pengenal, terutama cocok untuk pengujian saat ini.
3. Urutan Simulasi Output dan Simulasi Gangguan
Mampu mensimulasikan tes simulasi gangguan saluran listrik.
Fungsi Lanjutan :
1. Tes Standar IEC Built-In
Tes Standar IEC bawaan dapat diingat secara langsung.
2.3-fase operasi dan mode paralel
Dukungan operasi 3 fase, 3 unit secara paralelSpesifikasi teknis:
MODEL | SPS300VAC12000W | ||
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 75A | |
5 |
Power Factor @220Vac Input ,Full Load |
0.99 Min. Active PFC | |
6 | Effieciency |
>87% Max >86% @220Vac,50HZ input/230Vac,50HZ output |
|
3-Phase Output Mode | |||
7 | AC Power(Per Phase) | 4000VA | |
8 | AC Power(Total) | 12000VA | |
9 |
Max.Current (r.m.s) |
0~150V(L) | 32A |
0~300V(H) | 16A | ||
10 |
Max.Current (Peak) |
0~150V(L) | 160A |
0~300V(H) |
80A |
||
Parallel Phase Mode | |||
11 |
Max.Current (r.m.s) |
0~150V(L) | 96A |
0~300V(H) | 48A | ||
12 |
Max.Current (Peak) |
0~150V(L) | 480A |
0~300V(H) | 240A | ||
13 | Phase | 1 Phase | |
OUTPUT | |||
14 | Total Harmonic Distortion(THD) |
<0.5% (Resistive Load) at 15.0 -
70.0Hz and output voltage within the 80 - 140Vac at Low Range or the 160 -
280Vac at High Range <1% (Resistive Load) at 70.1 - 500Hz and output voltage within the 80 - 140Vac at Low Range or the 160 - 280Vac at High Range <1% (Resistive Load) at 501 - 1000Hz and output voltage within the 100 - 140Vac at Low Range or the 160 - 280Vac at High Range |
|
15 | Crest Factor(CF) | ≤5 | |
16 | Load Regulation |
+/-0.2%FS @15-100HZ(Resistive
Load) +/-0.5%FS @ Others Freq.(Resistive Load) |
|
17 | Line Regulation | ±0.1V | |
18 |
Voltage(AC) (L-N) |
Range | 0~300VAC, 150V/300V/Auto Mode |
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S at Voltage>3V | ||
19 |
Phase
Angle (Starting/Ending) |
Range | 0~359.9° |
Resclution | 0.1° | ||
Accuracy | ±1° @45~65Hz | ||
20 | Voltage(DC) | Range | 0~424VDC |
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S at Voltage>3V | ||
DC Power |
4000W | ||
Max.Current (L/H Range) (Per Phase) |
L 22.6A | ||
H 11.3A | |||
DC Power(Total) | 12000W | ||
Max.Current (L/H Range) (Total) |
L 67.8A | ||
H 33.9A | |||
Ripple&Noise(r.m.s) |
L <700mVrms
@Bandwidth 20HZ to 1MHZ |
||
Ripple&Noise(Peak) | <4000mVp-p @Bandwidth 20HZ to 1MHZ | ||
21 | Current OC Fold Mode | Resclution | 0.1A |
Accuracy | 2.0% of setting +1.0%F.S. | ||
Response Time | <1400ms | ||
22 | Frequency | Range | 15~1000Hz |
Resclution | 0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz) | ||
Accuracy | 0.03% of setting | ||
23 | Progrmmable Output Impedance | Not Support | |
24 | Harmonic & Inter-harmonics Simulation | Not Support | |
MEASUREMENT(Per Phase) | |||
25 |
Voltage (Per Phase) |
Range | AC 0~300VAC |
DC 0~424VDC | |||
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S. (Notes: Vpeak: 0.6% of setting +1%F.S.) | ||
26 |
Frequency (Per Phase) |
Range | 15~1000Hz |
Resclution | 0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz) | ||
Accuracy | 0.1% of setting | ||
27 |
Current* (r.m.s) (Per Phase) |
Range | H 0.3A~32A |
M 0.2A~20A | |||
L 0.1A~5A | |||
mA 0.02A~1.5A | |||
Resclution | 0.01A | ||
Accuracy | 0.4%+1.0%F.S. | ||
28 |
Current* (PEAK) (Per Phase) |
Range | 0A~163A |
Resclution | 0.01A | ||
Accuracy | 0.4%+1.5%F.S. | ||
29 |
Power (Per Phase) |
Range | 0~4080W |
Resclution | 0.1W | ||
Accuracy | 0.4% of setting +0.3%F.S at PF>0.2, Voltage >5V | ||
30 |
Power
Apparent |
Range | 0~4080VA |
Resclution | 0.1VA | ||
Accuracy | Voltage*Irms,Calculated value | ||
31 |
Power Resistive (VAR) (Per Phase) |
Range | 0~4080VAR |
Resclution | 0.1VAR | ||
Accuracy | √[(VA)^2-(W)^2],Calculated value | ||
32 |
Power Factor (PF) |
Range | 0.00~1.00 |
Resclution | 0.01 | ||
Accuracy | W/VA, Calculated value | ||
33 | Harmonic | Range | Not Support |
Extra Function | |||
34 | Slew Rate | Range | AC Voltage 0.001-1200.00V/mS and Disable |
DC Voltage 0.001-1000.00V/mS and Disable | |||
Frequency 0.001-1600.000HZ/ms and Disable | |||
35 | Remote Sense | Range | 5V(RMS), Max. Total power less than rated power |
36 | Cablibration |
Firmware-based cablibration through
the digital interface or front panel display Noted: Need Factory setting |
|
37 |
Test Mode | Not Support | |
38 | Graphic Display | 5.6'' Color touch LCD | |
39 | Operation Key Feature | Soft key,Numberic key,Rotary Knob,Support USB disk | |
40 | Rack mount Handles | YES | |
41 | FAN | Temperature Control | |
42 | Protection Circuits | OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP | |
43 | Interface | Standard USB,RS485,RS232, Option GPIB interface | |
Environmental | |||
44 | Operating Temperature | 0°C to 40°C | |
45 | Storage Temperature | -40°C to 85°C | |
46 | Altitude | 2000m | |
47 | Relative Humidity | 5-95%, non-condensing | |
48 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at FREQ | |
Mechanical | |||
49 | Dimensions(W*H*D) | 560x945x700 mm | |
50 | Unit Net Weight | 157.0kg |
Kategori Produk : Sistem Sumber AC Tiga Fasa > Sistem Sumber AC Tiga Fasa 12000W